TWO DRAWER TESTS REQUIRED

  • To test the ability of drawers and drawer mechanisms to operate with loading during normal use, drawers are loaded at 15 pounds per square foot and operated through 25,000 cycles. The drawers must then remain operable with no failure in any part of the drawer assembly or operating system, and drawer bottoms must not be deflected to interfere with drawer operation. The Two Drawer Test

  • To test the ability of doors, door-holding devices, hinges, and attachment devices to operate under the stress of normal use, doors are opened and closed through a full 90-degree swing for 25,000 cycles. At the test's conclusion, the door must be operable, the door-holding device must hold the door in closed position, hinges must show no visible signs of damage, connections between cabinet-and-hinge and door-and-hinge must show no sign of looseness, and other specifications must be met.